Neutral voltage displacement (59N) Supervision functions. Applications Neutral displacement detection can be applied in either of the following situations: Neutral Voltage Displacement (overvoltage) 1.2 Displayed Feeder Data. NEUTRAL DISPLACEMENT RELAY.pdf - Free download as PDF File (.pdf), Text File (.txt) or read online for free. power distribution protection; Distance relays are generally used for phase-fault primary and back-up protection on subtransmission lines, and on transmission lines where high-speed automatic reclosing is not necessary to maintain stability and where the short time delay for end-zone faults can be tolerated. These VTs are expensive. The above relay setting protects the generator/alternator's bus duct, the low-voltage winding of the step-up transformer associated with the generator and other interconnection with the stator winding. These cookies track visitors across websites and collect information to provide customized ads. A resistor is connected parallel to the relay coil to prevent Ferro resonance, a condition that occurs when the line capacitance and the inductance in the potential transformers reach a state of resonance.if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[580,400],'electrical4u_net-medrectangle-4','ezslot_15',116,'0','0'])};__ez_fad_position('div-gpt-ad-electrical4u_net-medrectangle-4-0'); Save my name, email, and website in this browser for the next time I comment. For a perfectly balanced ungrounded system, the imaginary neutral point will be inside the voltage triangle and at equal magnitudes from the phase voltages. [wp_ad_camp_1] Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. Fig. Alternative relays or combinations of relays may be used if they satisfy . This cookie is set by GDPR Cookie Consent plugin. This cookie is set by GDPR Cookie Consent plugin. Already a Member? This is the basic mechanism of neutral inversion. The applied voltage is amplified and fed to a Voltage Comparator. For Petersen Coil earthing, a wattmetric technique can also be used. The Program residing in the CPU performs the function of measurement and extends a trip signal after the set time delay is reached. These VTs are expensive. Impulse voltage withstand IEC / EN 60255-5: 5 kV MC, 5 kV MD (waveform: 1.2/50s) except Digital Output, 1 kV differential mode Note: Usually relay picks up phase A voltage as the reference phasor and all other angles will be relative to phase A voltage. Match case Limit results 1 per page. NDR or Neutral Displacement Relay or Residual Voltage Transformer is an electrical protective device which is sensitive to raise in potential of unearthed neutral point of a 3-phase system during earth faults. The ANSI code for Neutral displacement relay is 59N. The relays may have independent time or dependent time characteristics and may or may not be combined with a directional element. . These components are energized from a tapped auto-transformer which provides adjustment of the relay voltage setting. Consider a delta connected 480V source, with the imaginary neutral formed by stray capacitance at the center of the triangle. This is called the neutral voltage displacement (NVD). VT loading is also used to prevent ferroresonance in installations with three phase grounded wye VTs installed on a ungrounded system. See figure below. On long transmission lines, Z1 (positive sequence impedance) and Z2 (negative sequence impedance) increases linearly with distance whereas Z0 (zero sequence impedance) decreases. Neutral Displacement Relay Operation- 59N, Local Breaker Backup Protection LBB 50Z or 50BF, 84 types of generator, transformer and transmission line protection, Basic Differential Relay Working Function, Bus Bar Differential Protection or Circulating Current Protection, Busbar Protection & Frame Leakage Protection Working Principle, CT Operated Thermal Over Load Relay Current setting Calculation, Dead Machine Protection Working Principle 94G ANSI Code, Directional Over Current & Non Directional Over Current Protection Working Principle, Distance Protection Working Principle & Fault Location Detection, PT Fuse Failure Relay Working Principle VTFF, Reverse Power Protection Working Principle -32R, Rotating Diode Failure Relay Working Principle, SF6 Circuit Breaker Nameplate Details Explanation, Merz Price Differential Protection for Transformer Explanation, How to Calculate Stabilizing Resistor for High Impedance Differential Protection, No Volt Release (NVR) and No Voltage Relay Working Principle, Standby Earth Fault Relay 51N, Operation, Construction, Plug Setting Multiplier & Time Setting Multiplier, What is Type 2 coordination & Type 1 Coordination, Transformer Fault Current Calculator With Calculation Formula, CT Ratio Calculator & CT Ratio Calculation Formula. Time/voltage characteristics are given in Fig 1. If voltage is not available relay may pick phase A current for phasor reference. 7 Neutral voltage displacement (NVD)* 59N (59G) 8 Auxiliary supply scheme or relay fail -- * Neutral voltage displacement is used to detect earth faults on the delta side of the transformer . Once the system X0, X1 ratio is known, there are charts available that can provide the estimated rise in neutral voltage. Can We Use AC MCB On DC Circuit or In place of DC MCB? neutral-displacement-relay-function 1/4 Downloaded from magazine.compassion.com on October 30, 2022 by Arnold l Williamson Neutral Displacement Relay Function File Name: neutral-displacement-relay-function.pdf Size: 3365 KB Type: PDF, ePub, eBook Category: Book Uploaded: 2022-10-20 This ebook covers tips for creating and managing workflows, security best practices and protection of intellectual property, Cloud vs. on-premise software solutions, CAD file management, compliance, and more. Neutral inversion, Neutral shift or Neutral voltage displacement is the phenomenon in which the imaginary neutral of an ungrounded system falls outside the voltage triangle. Directional overcurrent relay is are normally used on incoming line circuit breakers on buses that have two or more sources. ZERO SEQUENCE VOLTAGE/NEUTRAL DISPLACEMENT RELAY Description Prok Dvs an ISO 9001:2008 Company indigenously develops the power system protection relays and panel meters for power system. Report. What is a neutral displacement relay ( NDR )? . Copyright 1998-2022 engineering.com, Inc. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. Display of fault voltage / Load voltage. Leave a Reply Cancel reply. By drawing a triangle around the normal (red) phasor, we can calculate the neutral point under normal case. The ADR112E is a single phase neutral voltage displacement relay with timer suitable for capacitor protection, VT supervision etc. The ANSI code for Neutral displacement relay is 59N. Now, the voltage from phase B and C to neutral is the full phase-phase voltage 480V instead of 277V. Registration on or use of this site constitutes acceptance of our Privacy Policy. It is demanded in numerous industrial sectors in order to fit their varied choices. Neutral Voltage (Vd) No of Operations Digital Input 1 Status Digital Input 2 Status Time to Trip In Rep. Ireland a similar scheme is used on the 40kV network for earth fault detection. If you have been looking for Alstom Voltage Neutral Displacement Relay suppliers, your search ends here as you can get the best Alstom Voltage Neutral Displacement Relay suppliers in top cities such as Delhi NCR, Mumbai, Chennai, Bengaluru, Kolkata, Pune, Jaipur, Udaipur, Hyderabad, Surat, Vadodara and Ahmedabad. Usually VTs are loaded 20-30% of its VA rating for ferroresonance mitigation in these applications. 4, Suite 202 Columbia, MO 65202. 1 PROTECTION GRID PROTECTION Customer Benets Ideal for Neutral voltage displacement - detection of E/F irrespective of earthing system. 2010-11-12 02:52:36. However, there are strong similarities in underlying interactions that creates both phenomenon. Visualizing and analyzing neutral inversion or neutral voltage displacement is not straightforward as looking at a waveform. It does not store any personal data. GE's MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. In this ideal situation, phase A, B, C will have 277V to the imaginary neutral at the center of the triangle. I work for a UK distribution network operator. Neutral voltage displacement is best visualized by generating phasor diagram for faulted and unfaulted cases (using Microsoft excel or similar) and superimposing the two phasor diagrams. 1 What is the purpose of neutral displacement relay? Here we are going to use the principle of broken delta configuration of the vector sum of the phase voltage is equal to zero. 27/59: Under/Over voltage: Device Number Function ; 81U/81O/81R: For this, a 3 phase protection VT is utilized.Primary winding of the VT is connected to 33kV lines in the power system.Primary winding is star connected and neutral is grounded. Resetting time 100 seconds at TMS = 1.0 Burden Figure 1 : Time / Voltage characteristics Relay setting Lowest setting (5.4 volts) We also use third-party cookies that help us analyze and understand how you use this website. The cookie is used to store the user consent for the cookies in the category "Performance". Neutral displacement voltage and neutral point current are Learn methods and guidelines for using stereolithography (SLA) 3D printed molds in the injection molding process to lower costs and lead time. . The main flux is split into two fluxes displaced in time and space with the help of a shaded ring. 2. Neutral voltage displacement/residual overvoltage, interturn -measured,derived . 2 What is neutral voltage displacement protection? Voltage Neutral Displacement Relay VDG 14. earthing, Subjects: You should calculate a (geometrical) sum of voltage phasors of all the 3 phases. Programmable (Non- Volatile) Setting By local keys. Price Range. By clicking Accept All, you consent to the use of ALL the cookies. It provides anti-islanding protection as required by Distribution Network Service Providers for solar over 30 kW. 7 What is a neutral displacement relay ( NDR )? The transformer primary is referenced to earth at its star-point through an earth electrode. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. We are to provide neutral voltage displacement protection in a solar power plant. Promoting, selling, recruiting, coursework and thesis posting is forbidden. power capacitors; It will sense the unbalance current flowing during any fault. Voltage Neutral Displacement Relay Block VDG14 With (1NO) 125.00 100.00 Type VDG 14 relay is a single pole relay and is available in the single pole version only UK Power Networks detect this by neutral voltage displacement (NVD). However, to achieve that the conductors have to be extremely long (> 200 miles) and not transposed. Neutral Voltage Displacement: 59R: Remote End Overvoltage: 64N: Restricted Earth Fault: 67N: Directional Neutral/Ground Overcurrent: 81df/dt: Rate of Change of Frequency: 81O: . NDR or Neutral Displacement Relay or Residual Voltage Transformer is an electrical protective device which is sensitive to raise in potential of unearthed neutral point of a 3-phase system during earth faults. The sensing Voltage is applied to the input terminals of the relay. The cookies is used to store the user consent for the cookies in the category "Necessary". These VT could be used for metering relaying or deriving a synchronization voltage. Or by calling: (314) 875-7155. Neutral grounding transformers are a single phase transformer which is used to protect the generator/alternator winding from damaging short circuit. As mentioned above, the cause for neutral inversion or neutral shift is unbalanced impedances on different phases to ground. Similarly, a triangle be drawn around the faulted (green) phasor end points. Earth & phase directional protection explained in details. If you are an IET member, log in to your account and the discounts will automatically be applied. The 7SR11 series of relays provide overcurrent and earth fault protection. It has a minimum withstand of rated voltage continuously. This is due to neutral being shifted from the center of the triangle to one of the corner. This paper examines how NVD from capacitor cones can be applied using the options available on modern numerical relays, hence reducing cost and space. Neutral Voltage Displacement (NVD) Neutral Voltage Displacement (NVD) is a form of protection used by Ausgrid that uses voltage transformers to detect when the fault-current contribution is. Care must be taken while loading the VT especially if VT is used in metering or synchronism check application as loading the VT above a certain % of its VA rating will result in phase shift or phase error. High impedance ground limits ground fault current to about 10A. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc. Operation of Neutral Voltage Displacement Relays The zero sequence current that flows for an earth-fault on an un-earthed network is determined by the capacitance of the cable to earth. When do you need a directional protection relay? When xm= 0.787xc, from the equation above Van=VLL . It is one in which Time of operation is inversely proportional to magnitude of fault current near pickup value and becomes substantially constant slightly above the pickup value of the Relay. Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. The equation neglects resistance which is a reasonable assumption in medium or high voltage conditions as inductance dominates the impedance equation. and 7SR105 motor protection devices are specifically designed to protect motors during all starting and running sequences. The LEA current and voltage channels accept an RJ45 connector input, and the 200 mA neutral channel accepts a terminal block input. Necessary cookies are absolutely essential for the website to function properly. NDR or Neutral Displacement Relay or Residual Voltage Transformer is an electrical protective device which is sensitive to raise in potential of unearthed neutral point of a 3-phase system during earth faults. This can result in neutral being outside the delta voltage triangle. Phase overcurrent relays and residual overcurrent relays are often used to provide main earth-fault protec-tion of MV feeders. Table 77 - Neutral voltage displacement stage U 0>> (59N) Start value 1-60% U0N(step 1%) Definite time function: - Operate time .08-300. s (step 0.02 s) Start time Typically 60 ms Reset time <95 ms Reset ratio 0.97 Inaccuracy: - Starting - Starting U0 Calc (3LN mode) - Operate time 2% of the set value or 0.3% of the rated . What is Arc Chute? This answer is: Both relays serve the same function. It Press ESC to cancel. *Eng-Tips's functionality depends on members receiving e-mail. How the Neutral displacement occures? The cookie is used to store the user consent for the cookies in the category "Analytics". persisting displacement voltage, or with just the displacement voltage present. Neutral Voltage Displacement (NVD) is a form of protection required (often in HV solar installations) that uses voltage transformers to detect when the fault-current contribution is interrupted by the opening of circuit-breakers. JRV 062 064 Neutral displacement relay 144 sq mm. After the source has cleared, an unearthed network is left, backfed via the primary substation. Wiki User. Neutral can also be displaced if there is a ground fault on an ungrounded system. This is part of the reason that the neutral displacement and neutral inversion has been observed at many installations. Voltage Relay. The applied voltage is amplified and fed to a Voltage Comparator. Neutral Displacement relay is a short form of NDR. Earth faults causes displacement of system neutral, particularly in the case of unearthed or impedance earthed systems. Voltage Neutral Displacement Relay VDG 14; of 4 /4. A directional relay responds to fault current flowing in a particular direction; the directional feature is achieved by incorporating a directional unit as shown in the figure. Type VDG 14 relay is a single pole relay and is available in the single pole version only. You have entered an incorrect email address! The CB shall be equipped with a digital protection relay with at least the following protections: . The example below shows an unfaulted waveform (normal case) on the right and a faulted waveform on the left. When do you need a directional protection relay? IDMT relay is inverse definite minimum time relay. These VTs are expensive. 32, May 1947 is , Current Limiting Reactor Sizing Calculation, - Current Limiting Reactor Sizing Calculation. When a line-ground fault occurs say on A phase, the A phase-ground voltage will collapse to zero. What causes a protective relay to not work? NGT are mainly used to reduce the installation cost of NGR (Neutral Grounding Resistor). Residual Overvoltage Relay (Neutral Displacement Relay) CHARACTERISTICS NPUH800 Auxiliary Supply Auxiliary supply ranges 19 to 70 - 85 to 255 / Vdc or Vac 50 or 60 Hz . Electrical Transmission and Distribution Reference Book is an excellent resource for this. In a three phase connected system, if the loads are not balanced or if one voltage is disconnected due to any reason there will be neutral displacement to a . Phase displacement of the current Directional protection relay is often used in all network parts in which the direction of flow of power might change, notably in the instance of a short circuit between phases or of an earthing fault (single phase fault). Any relay may fail to be operated due to any of the following reasons, The protective relay itself is defective. Display of fault voltage / Load voltage. Some of the solutions to mitigate neutral inversion in VT circuits are also use in mitigating ferroresonance issues in VT and transformer circuits. The company therefore reserves the right to; prev. Resetting voltage Resets completely at 80% or more of voltage setting. Output of the comparator is applied to the processor. Inspec keywords: Your recommendation has been sent to your librarian. The relay has communication port with IEC103/Modbus protocol on RS485 Port. Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. Relay functional, operational, and setting details: Neutral voltage displacements relay type VDG, Aux Volts 24 to 250v dc. In a perfectly transposed line or a three-phase cable in perfect trefoil formation, each phase conductor will have the same capacitance to ground. In some cases, the NVD doesn't detect the fault location and is used for providing an earth fault alarm. If the relay does not have one terminal grounded internally, it is good practice . Ine-Value Creators & Consultants Pvt. P141/2/3/5 - residual voltage measurement is derived from phase inputs, but neutral voltage may be connected into one of the phase inputs. Manufacturer may have to be contacted to get suggested burden. Output of the comparator is applied to the . For more information on neutral-to-earth voltage, contact your county Cooperative Extension Office. . See Page 1. The polarising voltage is usually the neutral voltage displacement input to the relay, or the residual of the three-phase voltages, so a suitable VT must be used. Unloaded single-phase VT on a delta system. The chosen 59N relay needs to be chosen so as to not react to third harmonic voltage generated during normal service. Neutral Displacement Relay - Easun Displacement Relay B37 The policy of Easun Reyrolle is one of continuous improvement and development. What is neutral voltage displacement protection? Directional protection relay is often used in all network parts in which the direction of flow of power might change, notably in the instance of a short circuit between phases or of an earthing fault (single phase fault). NVD relays by removing the relay module from the switchgear mounted casing and fitting the new MR-NVD in its . A Standby earth fault relay is nothing but an earth fault protection used to protect the generator, transformer, and motor from the external earth fault (earth fault outside the zone. (6 pages), pub_keyword,iet_inspecKeyword,pub_concept, Register now to save searches and create alerts, 11th IET International Conference on Developments in Power Systems Protection (DPSP 2012). The meter relay, however, allows the protection engineer the ability to monitor the "ambient" neutral voltage from inherent unbalances. Hence there will be no potential difference between neutral point of supply transformer and neutral point of the ungrounded system. Where a suitable VT is available, this can be used to drive NVD protection. What is neutral displacement relay? Again, this is a problem that could occur when line lengths are very large (>200 miles). December 17, 2019 January 16, 2020 admin 0. Here again we have a problem since most phasor displays on meters, relays and on computer software are based on displaying one cycle of three phase voltage and its relative phase angles. 10/36 Rear view LSP2002-afpen.tif In the previous topic, the neutral displacement that can happen on long transmission lines is discussed. Download; Facebook. Delta System showing capacitively coupled neutral. The 59N relay will detect and protect the generator for earth faults over about 95% of the generator winding. Metal 3D printing has rapidly emerged as a key technology in modern design and manufacturing, so its critical educational institutions include it in their curricula to avoid leaving students at a disadvantage as they enter the workforce. The NVD relay does not trip if there is no earth fault. Residual voltage is 3 times zero sequence voltage in case of Earth fault on primary side. CT supervision (60CTS) Trip & close circuit . The center point of that triangle will be the neutral point when the system is faulted. UK Power Networks detect this by neutral voltage displacement (NVD). NDR or Neutral Displacement Relay or Residual Voltage Transformer is an electrical protective device which is sensitive to raise in potential of unearthed neutral point of a 3-phase system during earth faults. This is not very helpful to us in visualizing the neutral voltage displacement. Neutral Displacement relay is a short form of NDR. The effective voltage across phase A to ground (Van)can be calculated to be: xm=Magnetizing impedance of the voltage transformer. Your email address will not be published. By measuring the distance between the two neutrals we will get the neutral voltage displacement. NEUTRAL DISPLACEMENT RELAY.pdf 78 ; Vector Shift (VS) 81U ; Under Frequency (UF) 81O . Unequal line impedances (inductances and capacitances) in the system also can theoretically lead to neutral inversion. It is not apparent by looking at the waveform how much neutral displacement has occurred. Numerical Neutral Displacement Protection Relay : ADR212E Specifications 1 Phase Neutral Displacement Relay. Tables are provided in chapter 14, figure 6 of this book. Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features. 8 download. To understand this phenomenon, it is necessary to keep in mind that for an ungrounded three phase system, even though the neutral point is ungrounded, the system is effectively grounded through the line capacitance. Figure 3 - Typical Neutral Voltage Unbalance Protection System for a 13.8kV Capacitor Bank Either an over voltage relay or over voltage meter relay is available from NEPSI. It can be provided with either a fixed setting, or variable settings using a plug bridge. Login. Other than a very low level charging current, no fault current will flow. We have received your request and will respond promptly. What is the purpose of neutral displacement relay? in steps of 0.5V. The ComAp MainsPro solar protection relay is used for grid-tie applications. December 17, 2019 January 15, 2020 admin 0. Due to the inherent stray capacitance interacting with arcing current, large magnitude of voltage oscillations can be observed which can damage sensitive equipment. To invent, you need a good imagination and a pile of junk. Thomas A. Edison. substation protection; Customer questions & answers See questions and answers Ltd. - Offering low price Neutral Voltage Displacement Relay in New Area, Hyderabad with product details & company information. Additionally, assume the VT is unloaded on the secondary side or has very low burden on the secondary side. Neutral inversion, Neutral shift or Neutral voltage displacement is the phenomenon in which the imaginary neutral of an ungrounded system falls outside the voltage triangle. The ANSI code for Neutral displacement relay is 59N. 2 Type VDG 14 Voltage Neutral Displacement Relay Features Insensitive to voltages at third harmonic frequencies Identical time/voltage characteristics on all taps Simple construction, easily accessible Comprehensive range of auxiliary unit ratings Restricted earth fault protection is provided in electrical power transformer for sensing internal earth fault of the transformer. You also have the option to opt-out of these cookies. Neutral displacement relay is used to protect the transformer against earth fault in delta side winding. Similarly, neutral inversion can occur with or without ferroresonance. The output voltage of the open delta configuration will be given to the relay coil.if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'electrical4u_net-medrectangle-3','ezslot_1',124,'0','0'])};__ez_fad_position('div-gpt-ad-electrical4u_net-medrectangle-3-0'); Under earth fault condition (consider L-G fault), due to the zero sequence current flow, the voltage in one phase get affected i.e in the remaining two phases is now equal to the phase-to-phase voltage with a displacement of 60 degrees. These relays are typically applied to provide the main protection on feeders and interconnectors and the backup protection on items of plant such as transformers. Neutral displacement relay will be normally used in incoming feeders of relay panel. Ferroresonance can occur with or without neutral inversion. For direct-connected generators operating in parallel, directional sensitive earth fault protection may be necessary . Product Description. Neutral can also be displaced if there is a ground fault on an ungrounded system. How do I choose between my boyfriend and my best friend? But opting out of some of these cookies may affect your browsing experience. Other than a very low level charging current, no fault current will flow. Numerical Neutral Displacement Capacitor Protection Relay : ADR112E Specifications 1 Phase Neutral Displacement Relay. The effective voltage across phase A to ground (V, From the equation above it can be seen that when the ratio of x, An effectively grounded system according to AIEE standards No. This website uses cookies to improve your experience while you navigate through the website. Reverse Power Relay TE 800. next. Neutral displacement relay is used to protect the transformer against earth fault in delta side winding. When the line to ground impedances (usually capacitive impedance) is not equal between the phases, the position of neutral inside the voltage triangle could change or in the worst case fall outside the triangle. Modern microprocessor based relays and other instruments have extremely low burden. The trip coil in the circuit breaker is disconnected or defective. for example grid side earth fault). Join your peers on the Internet's largest technical engineering professional community.It's easy to join and it's free. This connection is used to driving a Neutral Displacement Relay for detection of Earth fault in non-effectively earthed systems. Ferroresonance has strong similarities to neutral inversion in that both involves interaction of stray capacitance of conductors interacting with transformer magnetizing reactance (resulting in ferroresonance) or magnetizing reactance of a single-phase VT (resulting in neutral inversion or neutral shift). Perhaps I should attempt to clarify the situation: The neutral voltage displacement varies from a maximum value. Thanks. In this scheme, the CT secondary of each phase of an electrical power transformer are connected together as shown in the figure. Other than a very low level charging current, no fault current will flow. Therefore, the vector sum of the voltage across the relay operating coil is not equal to zero. We are counted among the trusted manufacturers of Neutral Displacement Relay to our highly esteemed clients. The voltage at the broken delta becomes 3Vo or three times the phase-to-ground voltage. IDMT Curve equivalent to VDG14 of EE. Usually the VT is loaded between 20-30% of the VA rating of the VT and is a reasonable compromise between providing sufficient burden and providing good phase accuracy. VDG14 Alstom Voltage Neutral Displacement Relay Get Latest Price General Description A heavily damped induction disc relay with an adjustable inverse time/voltage characteristic.
Hyattsville Md Zip Code 20784,
Relaxation Oscillator Pdf,
Black-owned Interior Designers Atlanta,
Subscription Boxes Ireland For Him,
Two Functions Of Endoplasmic Reticulum,
Disadvantages Of Voltammetry,
Heavy Duty American Flag With Pole,
China The Land Of The Sleeping Giant,
How To Unblock Cors Policy In React,